Integration of Phase Change Materials in Service Areas of Building Envelopes for Improved Thermal Performance: An Experimental Study in Saudi Arabia

Auteur(s):
ORCID


Médium: article de revue
Langue(s): anglais
Publié dans: Buildings, , n. 4, v. 14
Page(s): 904
DOI: 10.3390/buildings14040904
Abstrait:

This experimental study explores the integration of Phase Change Materials (PCMs) within building envelopes. The research specifically centers on the utilization of two microencapsulated paraffin-based PCMs with melting points of 37 °C and 43 °C. The study assesses their performance within cement and gypsum-based PCM composites, concentrating on service areas often overlooked in thermal analysis, including underground garages, staircases, and utility rooms. The experimental setup included constructing three chambers inside an underground garage during the hot months of June and July in Saudi Arabia. Two chambers were assigned to integrate the PCM, while the third chamber served as a control without PCM. The experiment unfolds in two phases. In the initial phase, the objective was to determine which PCM is more effective in reducing the heat load inside the chambers. This led to the adoption of the 43 °C PCM for the subsequent stage. The adoption of the 43 °C PCM resulted in a fourfold decrease in heat compared to the 37 °C PCM. The second phase investigates the integration of the selected PCM with cement and gypsum composites. The percentage of PCM incorporated into the concrete and gypsum composites was determined experimentally. For cement-based composites, the identified percentage that maintains material integrity is 20%, and for gypsum-based composites, it is 22%. The findings demonstrate a significant reduction in cooling load with PCM incorporation, with cement-based composites exhibiting superior thermal performance compared to gypsum-based alternatives and reducing the heat load by approximately 63%. Additionally, it was observed that concrete reduced the highest temperature during the day by 5.2 °C, which equates to about a 10% reduction, further enhancing comfort. Conducted over the course of two summer seasons, this study contributes valuable insights toward improving the quality of life for building occupants, considering various factors such as their living environment.

Copyright: © 2024 by the authors; licensee MDPI, Basel, Switzerland.
License:

Cette oeuvre a été publiée sous la license Creative Commons Attribution 4.0 (CC-BY 4.0). Il est autorisé de partager et adapter l'oeuvre tant que l'auteur est crédité et la license est indiquée (avec le lien ci-dessus). Vous devez aussi indiquer si des changements on été fait vis-à-vis de l'original.

  • Informations
    sur cette fiche
  • Reference-ID
    10774000
  • Publié(e) le:
    29.04.2024
  • Modifié(e) le:
    05.06.2024
 
Structurae coopère avec
International Association for Bridge and Structural Engineering (IABSE)
e-mosty Magazine
e-BrIM Magazine